Note
QST, Dec 1966, p. 143.
QST, Mar 1968, p. 114.
QST, Dec 1976, p. 157.
B&W product catalog, Nov 1987.
Available in 1000 and 1500 watt models (same model number) (QST, Jan 1967, p. 131).
After 1970, this was sold under the Barker & Williamson (B&W) label.
Rated to 1500 watts input (intermittent). Meter ranges are individually calibrated for highest accuracy.
Specifications
– Frequency Range: DC to 300 MHz
– VSWR: Less than 1.3:1 to 230 MHz
– Power Handling: 1500 watts continuous/intermittent RF input. – Warning light signals maximum heat limit.
– Wattmeter Ranges: 0–15, 0–50, 0–300, and 0–1500 watts
– Accuracy: 5% of full scale
– nput Connector: SO-239 (50 ohms)
References
Review. 73, Mar 1967, p. 106.